Note: Internal diamagnetic flux measurements on ASDEX Upgrade

Show simple item record

dc.contributor.author Giannone, L.
dc.contributor.author Fischer, R.
dc.contributor.author Fuchs, J. C.
dc.contributor.author Geiger, B.
dc.contributor.author Maraschek, M.
dc.contributor.author Rittich, D.
dc.contributor.author Sieglin, B.
dc.contributor.author Bock, A.
dc.contributor.author Hobirk, J.
dc.contributor.author Kallenbach, A.
dc.contributor.author Mertens, V.
dc.contributor.author Schuhbeck, K. H.
dc.contributor.author McCarthy, Patrick J.
dc.date.accessioned 2020-03-11T10:24:58Z
dc.date.available 2020-03-11T10:24:58Z
dc.date.issued 2018-10-01
dc.identifier.citation Giannone, L., Fischer, R., Fuchs, J. C., Geiger, B., Maraschek, M., Rittich, D., Sieglin, B., Bock, A., Hobirk, J., Kallenbach, A., Mertens, V., Schuhbeck, K. H. and McCarthy, P. J. (2018) 'Note: Internal diamagnetic flux measurements on ASDEX Upgrade', Review of Scientific Instruments, 89(10), 106101 (3 pp). doi: 10.1063/1.5045543 en
dc.identifier.volume 89 en
dc.identifier.startpage 1 en
dc.identifier.endpage 3 en
dc.identifier.issn 0034-6748
dc.identifier.uri http://hdl.handle.net/10468/9749
dc.identifier.doi 10.1063/1.5045543 en
dc.description.abstract Internal diamagnetic flux measurements, with measurement loops and compensation magnetic probes inside the vacuum vessel, are now available on the ASDEX Upgrade tokamak. The measured diamagnetic flux is compared to that predicted by simulations and calculated from equilibrium reconstruction. The diamagnetic flux measured at 2 positions separated toroidally by 180 in the vacuum vessel is compared. en
dc.format.mimetype application/pdf en
dc.language.iso en en
dc.publisher AIP Publishing en
dc.relation.uri https://aip.scitation.org/doi/10.1063/1.5045543
dc.rights © 2018, AIP Publishing. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Review of Scientific Instruments and may be found at https://doi.org/10.1063/1.5045543 en
dc.subject Plasma properties and parameters en
dc.subject Plasma confinement en
dc.subject Tokamaks en
dc.subject Electron density en
dc.subject Plasma heating en
dc.title Note: Internal diamagnetic flux measurements on ASDEX Upgrade en
dc.type Article (peer-reviewed) en
dc.internal.authorcontactother Pádraig Mac Cárthaigh, Physics, University College Cork, Cork, Ireland. +353-21-490-3000 Email: pjm@ucc.ie en
dc.internal.availability Full text available en
dc.date.updated 2020-03-11T10:14:19Z
dc.description.version Published Version en
dc.internal.rssid 456735017
dc.contributor.funder Horizon 2020 en
dc.contributor.funder H2020 Euratom en
dc.description.status Peer reviewed en
dc.identifier.journaltitle Review of Scientific Instruments en
dc.internal.copyrightchecked Yes
dc.internal.licenseacceptance Yes en
dc.internal.IRISemailaddress pjm@ucc.ie en
dc.identifier.articleid 106101 en
dc.relation.project info:eu-repo/grantAgreement/EC/H2020::COFUND-EJP/633053/EU/Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium/EUROfusion en
dc.identifier.eissn 1089-7623


Files in this item

This item appears in the following Collection(s)

Show simple item record

This website uses cookies. By using this website, you consent to the use of cookies in accordance with the UCC Privacy and Cookies Statement. For more information about cookies and how you can disable them, visit our Privacy and Cookies statement