Note: Internal diamagnetic flux measurements on ASDEX Upgrade
Giannone, L.; Fischer, R.; Fuchs, J. C.; Geiger, B.; Maraschek, M.; Rittich, D.; Sieglin, B.; Bock, A.; Hobirk, J.; Kallenbach, A.; Mertens, V.; Schuhbeck, K. H.; McCarthy, Patrick J.
Date:
2018-10-01
Copyright:
© 2018, AIP Publishing. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Review of Scientific Instruments and may be found at https://doi.org/10.1063/1.5045543
Citation:
Giannone, L., Fischer, R., Fuchs, J. C., Geiger, B., Maraschek, M., Rittich, D., Sieglin, B., Bock, A., Hobirk, J., Kallenbach, A., Mertens, V., Schuhbeck, K. H. and McCarthy, P. J. (2018) 'Note: Internal diamagnetic flux measurements on ASDEX Upgrade', Review of Scientific Instruments, 89(10), 106101 (3 pp). doi: 10.1063/1.5045543
Abstract:
Internal diamagnetic flux measurements, with measurement loops and compensation magnetic probes inside the vacuum vessel, are now available on the ASDEX Upgrade tokamak. The measured diamagnetic flux is compared to that predicted by simulations and calculated from equilibrium reconstruction. The diamagnetic flux measured at 2 positions separated toroidally by 180 in the vacuum vessel is compared.
Show full item record