Formation of a robust and stable film comprising ionic liquid and polyoxometalate on glassy carbon electrode modified with multiwalled carbon nanotubes: Toward sensitive and fast detection of hydrogen peroxide and iodate
dc.contributor.author | Haghighi, Behzad | |
dc.contributor.author | Hamidi, Hassan | |
dc.contributor.author | Gorton, Lo | |
dc.contributor.funder | Institute for Advanced Studies in Basic Sciences | en |
dc.contributor.funder | Styrelsen för Internationellt Utvecklingssamarbete | en |
dc.contributor.funder | Vetenskapsrådet | en |
dc.date.accessioned | 2022-09-01T12:07:47Z | |
dc.date.available | 2022-09-01T12:07:47Z | |
dc.date.issued | 40260 | |
dc.date.updated | 2022-09-01T11:21:35Z | |
dc.description.abstract | A robust and stable film comprising n-octylpyridinum hexafluorophosphate ([C8Py][PF6]) and 1:12 phosphomolybdic acid (PMo12) was prepared on glassy carbon electrodes modified with multiwall carbon nanotubes (GCE/MWCNTs) by dip-coating. The cyclic voltammograms of the GCE/MWCNTs/[C8Py][PF6]-PMo12 showed three well-defined pairs of redox peaks due to the PMo12 system. The surface coverage for the immobilized PMo12 and the average values of the electron transfer rate constant for three pairs of redox peaks were evaluated. The GCE/MWCNTs/[C8Py][PF6]-PMo12 showed great electrocatalytic activity towards the reduction of H2O2 and iodate. The kinetic parameters of the catalytic reduction of hydrogen peroxide and iodate at the electrode surface and analytical features of the sensor for amperometric determination of hydrogen peroxide and iodate were evaluated. | en |
dc.description.sponsorship | Institute for Advanced Studies in Basic Science (grant number G2009IASBS119); Styrelsen för Internationellt Utvecklingssamarbete (project number 348-2003-4947); Vetenskapsrådet (project number 621-2007-4124) | en |
dc.description.status | Peer reviewed | en |
dc.description.version | Accepted Version | en |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Haghighi, B., Hamidi, H. and Gorton, L. (2010) 'Formation of a robust and stable film comprising ionic liquid and polyoxometalate on glassy carbon electrode modified with multiwalled carbon nanotubes: Toward sensitive and fast detection of hydrogen peroxide and iodate', Electrochimica Acta, 55(16), pp. 4750-4757. doi: 10.1016/j.electacta.2010.03.041 | en |
dc.identifier.doi | 10.1016/j.electacta.2010.03.041 | en |
dc.identifier.endpage | 4757 | en |
dc.identifier.issn | 0013-4686 | |
dc.identifier.issued | 16 | en |
dc.identifier.journaltitle | Electrochimica Acta | en |
dc.identifier.startpage | 4750 | en |
dc.identifier.uri | https://hdl.handle.net/10468/13529 | |
dc.identifier.volume | 55 | en |
dc.language.iso | en | en |
dc.publisher | Elsevier B.V. | en |
dc.rights | © 2010, Elsevier Ltd. All rights reserved. This manuscript version is made available under the CC BY-NC-ND 4.0 license. | en |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Iodate | en |
dc.subject | Ionic liquid | en |
dc.subject | Modified electrode | en |
dc.subject | Phosphomolybdic acid | en |
dc.subject | H2O2 | en |
dc.title | Formation of a robust and stable film comprising ionic liquid and polyoxometalate on glassy carbon electrode modified with multiwalled carbon nanotubes: Toward sensitive and fast detection of hydrogen peroxide and iodate | en |
dc.type | Article (peer-reviewed) | en |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Hassan_Hamidi_Electrochimica_Acta2010.pdf
- Size:
- 1.26 MB
- Format:
- Adobe Portable Document Format
- Description:
- Accepted Version
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 2.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: