A portable multiplexed electrochemical biosensor for lactate and pH monitoring in calf saliva

Loading...
Thumbnail Image
Files
1-s2.0-S095656632600597X-mmc1.pdf(2.18 MB)
Appendix A. Supplementary Data
1-s2.0-S095656632600597X-main.pdf(4.82 MB)
Published Version
Date
2026-11-01
Authors
Adib, Md Ridwan
Higes-Marquez, Javier
Barrett, Colm
O'Sullivan, Shane
McFadden, Marie
Kennedy, Emer
O'Riordan, Alan
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Ltd
Research Projects
Organizational Units
Journal Issue
Abstract
Non-invasive biomarker assessment in saliva offers a promising route for early detection of bovine respiratory disease and scour in calves. However, accurate electrochemical sensing in this complex matrix remains challenging due to variable pH, viscosity, and interfering species. Here, we report an integrated dual-function interdigitated microelectrode (IDE) platform capable of simultaneous detection of lactate and pH, operating under an in-situ electrochemical pH control strategy to regulate the local sensing microenvironment and improve operational stability. Microband Au IDEs were fabricated using multilayer photolithography and metal deposition, followed by sequential surface modification with platinum black, o-phenylenediamine/β-cyclodextrin and lactate oxidase to enable selective and sensitive lactate detection. Finite element simulations confirmed rapid local acidification and oxygen generation at the protonator electrodes, enabling precise pH tuning at the sensing interface. The pH sensor exhibited a linear super Nernstian response from pH 3-9 in buffer (−66.0 mV.pH-1, R2 = 0.999), while the lactate biosensor demonstrated a linear range of 0.02-7 mM in artificial saliva, achieving a limit of detection of 0.6 μM with pH control. A portable, battery-powered electronics interface with wireless data transmission was developed and benchmarked against laboratory instrumentation, achieving comparable sensitivities for lactate (−0.47 nA mM-1) and pH (−117 mV.pH-1) in artificial saliva. In calf saliva, the platform accurately distinguished healthy vs. sick animals, consistent with clinical health scoring. This multiplexed, pH-regulated sensing system offers a robust pathway toward field-deployable, non-invasive diagnostic tools for rapid monitoring of animal health and welfare.
Description
Keywords
Dual sensing , Electrochemical lactate and pH sensor , Non-invasive technology , pH control , Saliva , Sensor electronics interface , [TyndallMicroNano] , [BEES]
Citation
Adib, M R, Higes-Marquez, J, Barrett, C, O'Sullivan, S, McFadden, M, Kennedy, E & O'Riordan, A 2026, 'A portable multiplexed electrochemical biosensor for lactate and pH monitoring in calf saliva', Biosensors and Bioelectronics, vol. 311, 118965, pp. 1-11. https://doi.org/10.1016/j.bios.2026.118965
Link to publisher’s version