A fast electrochemical impedance spectroscopy with a square wave as excitation signal for impedance-based biomedical applications
| dc.contributor.author | Wang, Zhongzheng | en |
| dc.contributor.author | Shao, Han | en |
| dc.contributor.author | O'Riordan, Alan | en |
| dc.contributor.author | Higes-Marquez, Javier | en |
| dc.contributor.author | O'Connell, Ivan | en |
| dc.contributor.author | O'Hare, Daniel | en |
| dc.contributor.funder | Science Foundation Ireland | en |
| dc.contributor.funder | Enterprise Ireland | en |
| dc.date.accessioned | 2025-07-16T11:30:46Z | |
| dc.date.available | 2025-07-16T11:30:46Z | |
| dc.date.issued | 2025-06-18 | en |
| dc.description.abstract | This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), to meet the requirements of portable, real-time biomedical impedance-based detections with Ultra-Microband (UMB) sensor. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the excitation signal, which achieves a fast, accurate EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. This work starts with the theoretical justification for treating the sensor as a Linear Time-Invariant (LTI), then the practical linear region for operating the sensor as an LTI system is experimentally verified and determined, which enables the capacity of employing the harmonics of a square wave for EIS measurements. A dynamic model of the charge-transfer resistance together with an approximated of the Constant Phase Element (CPE) are implemented with Verilog-A for simulations, and a circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 2.73% average Mean Absolute Percentage Error (MAPE), compared to a commercial electrochemical instrument AutoLab, with five pre-modified electrodes across four different concentrations of Ferrocene Carboxylic Acid (FcCOOH), demonstrating this method is suitable for portable, real-time label-free EIS biomedical detections and applications. | en |
| dc.description.status | Peer reviewed | en |
| dc.description.version | Accepted Version | en |
| dc.format.mimetype | application/pdf | en |
| dc.identifier.citation | Wang, Z., Shao, H., Riordan, A. O., Higes-Marquez, J., Connell, I. O. and Hare, D. O. (2025) 'A fast electrochemical impedance spectroscopy with a square wave as excitation signal for impedance-based biomedical applications', IEEE Transactions on Biomedical Circuits and Systems, 19(4), pp. 726–742. https://doi.org/10.1109/TBCAS.2025.3579698 | en |
| dc.identifier.doi | 10.1109/tbcas.2025.3579698 | en |
| dc.identifier.eissn | 1940-9990 | en |
| dc.identifier.endpage | 742 | |
| dc.identifier.issn | 1932-4545 | en |
| dc.identifier.journaltitle | IEEE Transactions on Biomedical Circuits and Systems | en |
| dc.identifier.startpage | 726 | |
| dc.identifier.uri | https://hdl.handle.net/10468/17709 | |
| dc.identifier.volume | 19 | |
| dc.language.iso | en | en |
| dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | en |
| dc.relation.ispartof | IEEE Transactions on Biomedical Circuits and Systems | en |
| dc.relation.project | info:eu-repo/grantAgreement/SFI/Research Centres Programme/16/RC/3835/IE/VistaMilk Centre/ | en |
| dc.rights | © 2025, IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | en |
| dc.subject | Ultra-microband | en |
| dc.subject | CV | en |
| dc.subject | EIS | en |
| dc.subject | TIA | en |
| dc.subject | FFT | en |
| dc.subject | Verilog-A | en |
| dc.subject | Sensor modelling | en |
| dc.subject | ~Tyndall National Institute - Journal Articles~ | en |
| dc.title | A fast electrochemical impedance spectroscopy with a square wave as excitation signal for impedance-based biomedical applications | en |
| dc.type | Article (peer-reviewed) | en |
| dc.type | journal-article | en |
| publicationissue.issueNumber | 4 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- A_Fast_Electrochemical_Impedance_Spectroscopy_with_A_Square_Wave_as_Excitation_Signal_for_Impedance-based_Biomedical_Applications.pdf
- Size:
- 4.44 MB
- Format:
- Adobe Portable Document Format
- Description:
- Accepted Version
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 2.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: