Investigation of lung volume measurements in neonates using gas in scattering media absorption spectroscopy

dc.contributor.authorPacheco, Andrea
dc.contributor.authorJayet, Bapiste
dc.contributor.authorGrygoryev, Konstantin
dc.contributor.authorMessina, Walter
dc.contributor.authorDehghani, Hamid
dc.contributor.authorKrite Svanberh, Emilie
dc.contributor.authorDempsey, Eugene M.
dc.contributor.authorAndersson-Engels, Stefan
dc.contributor.funderScience Foundation Irelanden
dc.date.accessioned2022-10-05T14:38:32Z
dc.date.available2022-10-05T14:38:32Z
dc.date.issued2022-04
dc.date.updated2022-10-05T14:35:03Z
dc.description.abstractWe perform phantom and numerical studies of the changes in molecular oxygen and water vapor spectroscopic signals, showing the potential of measuring pulmonary volume changes with GASMAS technique in neonates.en
dc.description.statusPeer revieweden
dc.description.versionPublished Versionen
dc.format.mimetypeapplication/pdfen
dc.identifier.articleidTW1B.4en
dc.identifier.citationPacheco, A., Jayet, B., Grygoryev, K., Messina, W., Dehghani, H., Svanberg, E.K., Dempsey, E. and Andersson-Engels, S. (2022) ‘Investigation of lung volume measurements in neonates using gas in scattering media absorption spectroscopy’, in Biophotonics Congress: Biomedical Optics 2022 (Translational, Microscopy, OCT, OTS, BRAIN), Fort Lauderdale, Florida, 24-27 April, Optica Publishing Group, TW1B.4. (2 pp). https://doi.org/10.1364/TRANSLATIONAL.2022.TW1B.4.en
dc.identifier.doi10.1364/TRANSLATIONAL.2022.TW1B.4en
dc.identifier.endpage2en
dc.identifier.isbn978-1-957171-03-6
dc.identifier.startpage1en
dc.identifier.urihttps://hdl.handle.net/10468/13746
dc.language.isoenen
dc.publisherOptica Publishing Groupen
dc.relation.ispartofBiophotonics Congress: Biomedical Optics 2022 (Translational, Microscopy, OCT, OTS, BRAIN)
dc.relation.projectinfo:eu-repo/grantAgreement/SFI/SFI Research Professorship Programme/15/RP/2828/IE/Novel applications and techniques for in vivo optical imaging and spectroscopy/en
dc.relation.urihttps://doi.org/10.1364/TRANSLATIONAL.2022.TW1B.4
dc.rights© 2022 The Author(s). Published by Optical Publishing Groupen
dc.subjectGASMAS techniqueen
dc.subjectNeonatesen
dc.subjectGas in scattering media absorption spectroscopy (GASMAS)en
dc.subjectAbsorption spectroscopyen
dc.subjectComputed tomographyen
dc.subjectLight propagationen
dc.subjectPhantom studiesen
dc.subjectScattering mediaen
dc.subjectTunable diode lasersen
dc.titleInvestigation of lung volume measurements in neonates using gas in scattering media absorption spectroscopyen
dc.typeConference itemen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Translational-2022-TW1B.4.pdf
Size:
425.78 KB
Format:
Adobe Portable Document Format
Description:
Published version
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.71 KB
Format:
Item-specific license agreed upon to submission
Description: