Evaluation of an integrated 3D-printed phantom for coronary CT angiography using iterative reconstruction algorithm

Loading...
Thumbnail Image
Date
2020
Authors
Abdullah, K. A.
McEntee, Mark F.
Reed, W.
Kench, P. L.
Journal Title
Journal ISSN
Volume Title
Publisher
John Wiley and Sons Ltd
Published Version
Research Projects
Organizational Units
Journal Issue
Abstract
Introduction: 3D-printed imaging phantoms are now increasingly available and used for computed tomography (CT) dose optimisation study and image quality analysis. The aim of this study was to evaluate the integrated 3D-printed cardiac insert phantom when evaluating iterative reconstruction (IR) algorithm in coronary CT angiography (CCTA) protocols. Methods: The 3D-printed cardiac insert phantom was positioned into a chest phantom and scanned with a 16-slice CT scanner. Acquisitions were performed with CCTA protocols using 120 kVp at four different tube currents, 300, 200, 100 and 50 mA (protocols A, B, C and D, respectively). The image data sets were reconstructed with a filtered back projection (FBP) and three different IR algorithm strengths. The image quality metrics of image noise, signal–noise ratio (SNR) and contrast–noise ratio (CNR) were calculated for each protocol. Results: Decrease in dose levels has significantly increased the image noise, compared to FBP of protocol A (P < 0.001). As a result, the SNR and CNR were significantly decreased (P < 0.001). For FBP, the highest noise with poor SNR and CNR was protocol D with 19.0 ± 1.6 HU, 18.9 ± 2.5 and 25.1 ± 3.6, respectively. For IR algorithm, the highest strength (AIDR3Dstrong) yielded the lowest noise with excellent SNR and CNR. Conclusions: The use of IR algorithm and increasing its strengths have reduced noise significantly and thus increased the SNR and CNR when compared to FBP. Therefore, this integrated 3D-printed phantom approach could be used for dose optimisation study and image quality analysis in CCTA protocols. © 2020 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology
Description
Keywords
Coronary CTA , Dose optimisation , Image quality , Phantom , Reconstruction settings
Citation
Abdullah, K. A., McEntee, M. F., Reed, W. and Kench, P. L. (2020) 'Evaluation of an integrated 3D‐printed phantom for coronary CT angiography using iterative reconstruction algorithm', Journal of Medical Radiation Sciences, 67(3), pp.170-176. doi: 10.1002/jmrs.387
Link to publisher’s version