Carbon fibre cloth-supported iridium oxide/polyaniline bilayer electrode for solid-state potentiometric pH sensing
| dc.contributor.author | Rasel, Md | |
| dc.contributor.author | Jamal, Mamun | |
| dc.contributor.author | Padmanathan, N. | |
| dc.contributor.author | Razeeb, Kafil M. | |
| dc.contributor.funder | University Grants Commission of Bangladesh | |
| dc.contributor.funder | Ministry of Science & Technology of Bangladesh | |
| dc.contributor.funder | Khulna University of Engineering & Technology (KUET) | |
| dc.date.accessioned | 2026-09-09T11:18:01Z | |
| dc.date.available | 2026-09-09T11:18:01Z | |
| dc.date.issued | 2026-07-23 | |
| dc.description.abstract | In this work, a stable solid-state potentiometric pH sensor was developed by integrating an iridium oxide/polyaniline (IrO2/PANI) bilayer onto conductive carbon fibre cloth (CFC). The resulting IrO2/PANI/CFC electrode was fabricated through sequential PANI electropolymerization followed by IrO2 electrodeposition, forming a binder free hybrid interface that combines the proton responsive conductivity of PANI with hydrated/hydroxylated proton active iridium oxide sites. Morphological, elemental, vibrational, and surface chemical analyses confirmed the successful formation of the IrO2/PANI sensing layer on the CFC substrate. The electrode exhibited a near-Nernstian response over pH 3–11, with a sensitivity of 58.4 ± 0.9 mV pH−1, good linearity and an estimated pH resolution of approximately 0.01 pH unit. During continuous pH adjustment in Britton–Robinson buffer from pH 4.5 to 11.1, the electrode maintained a comparable sensitivity of 56.8 ± 1.1 mV pH−1 without removing or washing the sensor. The electrode also showed limited interference from common cations, reversible pH tracking behaviour, acceptable short-term drift and 96.3% sensitivity retention after 45 days of repeated measurement and storage. Real-sample analysis of vinegar, orange juice, and baking powder solution showed good agreement with a commercial glass membrane pH meter. These results demonstrate the potential of IrO2/PANI/CFC as a low-cost platform for stable potentiometric pH sensing in practical sample environments. | en |
| dc.description.sponsorship | University Grant Commission of Bangladesh|Phy Sci-38-2023-24 | |
| dc.description.sponsorship | Ministry of Science & Technology of Bangladesh|SRG-252361 | |
| dc.description.version | Published Version | |
| dc.format.extent | 12 | |
| dc.format.mimetype | application/pdf | en |
| dc.identifier.authororcid | Rasel, Md | |
| dc.identifier.authororcid | Jamal, Mamun | |
| dc.identifier.authororcid | Padmanathan, N. | |
| dc.identifier.authororcid | Razeeb, Kafil M.§0000-0001-9360-9277 | |
| dc.identifier.citation | Rasel, M, Jamal, M, Padmanathan, N & Razeeb, K M 2026, 'Carbon fibre cloth-supported iridium oxide/polyaniline bilayer electrode for solid-state potentiometric pH sensing', RSC Advances, vol. 16, no. 38, pp. 42528-42539. https://doi.org/10.1039/d6ra05424b | |
| dc.identifier.doi | 10.1039/d6ra05424b | |
| dc.identifier.endpage | 42539 | |
| dc.identifier.issn | 2046-2069 | |
| dc.identifier.issued | 38 | |
| dc.identifier.journaltitle | RSC Advances | |
| dc.identifier.startpage | 42528 | |
| dc.identifier.uri | https://hdl.handle.net/10468/19206 | |
| dc.identifier.volume | 16 | |
| dc.language.iso | en | |
| dc.publisher | Royal Society of Chemistry | |
| dc.relation.uri | https://www.scopus.com/pages/publications/105046215353 | |
| dc.rights | © 2026, the Author(s). Published by the Royal Society of Chemistry. This article is licensed under a Creative Commons Attribution 4.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given. | |
| dc.rights.accessrights | open access | |
| dc.rights.licensename | Attribution 4.0 International | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.status | Peer reviewed | |
| dc.subject | Stable solid-state potentiometric pH sensor | |
| dc.subject | [TyndallIPES] | |
| dc.subject | Bilayer | |
| dc.subject | Polyaniline (PANI) | |
| dc.subject | Iridium oxide (IrO2) | |
| dc.subject | Conductive carbon fiber cloth (CFC) | |
| dc.title | Carbon fibre cloth-supported iridium oxide/polyaniline bilayer electrode for solid-state potentiometric pH sensing | en |
| dc.type | Article (peer-reviewed) |