A novel comparative study for simultaneous determination of Cd (II) and Pb (II) based on ruthenium complex-nanoparticles-nafion modified screen-printed gold electrode

Loading...
Thumbnail Image
Files
1-s2.0-S0925400522019165-main.pdf(3.18 MB)
Published Version
1-s2.0-S0925400522019165-mmc1.docx(170.72 KB)
Supplementary Material
Date
2023-04
Authors
Albalawi, Ibtihaj
Hogan, Anna
Alatawi, Hanan
Alsefri, Samia
Moore, Eric
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier
Research Projects
Organizational Units
Journal Issue
Abstract
A novel and effective method for immobilization of active ruthenium (II) bipyridine complex on screen printed gold electrode surface was developed for simultaneous determination of Cd (II) and Pb (II) in an environmental water sample. The electrostatic interaction between negatively charged graphene oxide (GO) or citrate-capped gold nanoparticles (AuNPs) and positively charged ruthenium (II) bipyridine complex ([Ru(bpy)3]2+) was studied with the incorporation of cation exchanging Nafion polymer, which enhanced electron transfer rate, reduced the interference caused by active compounds and results in long term stability. The comparison between the hybrid Ru-GO/Nafion and Ru-Au/Nafion nanocompositesâ behavior was electrochemically investigated in this paper through cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave anodic stripping voltammetry (SWASV). Additionally, the surface morphologies of the screen-printed electrode were evaluated using energy-dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM). The proposed Ru-GO/Nafion sensor exhibited a higher sensitivity towards cadmium ion with a detection limit of 4.2 ppb compared to the Ru-Au/Nafion assay, which reveals low sensitivity with a limit of detection of 12.01 ppb. The developed assays show excellent electrochemical performance towards lead ions with a detection limit of 5.3 ppb and 2.5 ppb for Ru-GO/Nafion and Ru-Au/Nafion, respectively, indicating that the lead ions can be accumulated more on the surface of Ru-Au/Nafion SPGE. The hybrid nanocomposite assays were successfully employed in river and tap water samples and validated using Atomic Absorption Spectroscopy (AAS).
Description
Keywords
Gold-citrated , Graphene oxide , Heavy metal ions , Nafion , Ruthenium (II) bipyridine , Screen printed electrode
Citation
Albalawi, I., Hogan, A., Alatawi, H., Alsefri, S. and Moore, E. (2023) ‘A novel comparative study for simultaneous determination of Cd (Ii) and Pb (Ii) based on ruthenium complex-nanoparticles-nafion modified screen-printed gold electrode’, Sensors and Actuators B: Chemical, 380, 133273 (11pp). doi: 10.1016/j.snb.2022.133273
Link to publisher’s version